Mitech XXHA-2505 Inflatable X-ray
Rp123
The Mitech XXHA-2505 is a portable inflatable X-ray flaw detector developed for accurate non-destructive testing (NDT) of internal flaws in various materials. Utilizing the principle of differential X-ray absorption based on material thickness and density, this unit provides reliable detection of cracks, voids, inclusions, and other internal defects. Its lightweight design, compact structure, and digital control interface make it an excellent choice for field operations and harsh environments.
Mitech XXHA-2505 Inflatable X-ray Flaw Detector
Portable Radiographic Testing System for Industrial NDT Applications
The Mitech XXHA-2505 is a portable inflatable X-ray flaw detector developed for accurate non-destructive testing (NDT) of internal flaws in various materials. Utilizing the principle of differential X-ray absorption based on material thickness and density, this unit provides reliable detection of cracks, voids, inclusions, and other internal defects. Its lightweight design, compact structure, and digital control interface make it an excellent choice for field operations and harsh environments.
Suitable for use with portable generators, the XXHA-2505 is ideal for industries such as shipbuilding, aerospace, petrochemicals, and pressure vessel manufacturing. It delivers sharp radiographic images without requiring special surface preparation or being affected by material grain size.
Key Features
-
microcomputer-controlled system for high precision and stability
-
compact and portable design for on-site use
-
over-temperature protection that automatically cuts off high-voltage output
-
adjustable kV settings to match various materials and inspection needs
-
stable current control through pulse frequency modulation
-
anti-interference circuitry for reliable operation in high-voltage environments
-
error detection with real-time fault display codes
-
1:1 duty cycle for balanced exposure and cooling intervals
-
delayed high-voltage start function for improved operator safety
-
high-voltage isolation ensures safer system design
-
compatible with portable power generators for remote inspections
Applications
The XXHA-2505 is widely used in:
-
shipbuilding and marine engineering
-
machinery and metal fabrication
-
aerospace and aviation maintenance
-
railway infrastructure inspections
-
pressure vessel and boiler testing
-
oil and gas pipeline inspections
-
chemical and petrochemical industries
-
national defense and military equipment evaluation
Working Principle
The system generates X-rays by converting AC power into high-voltage DC pulses. These pulses energize an X-ray tube, where electrons are accelerated toward the anode. Upon striking the target material, the X-rays penetrate the object under inspection. Internal inconsistencies reduce the intensity of X-rays differently, and this is captured on special film.
After chemical processing, defects appear as dark or light areas on the radiograph, based on how much radiation passed through. This contrast allows users to assess flaw type, size, and location.
Technical Specifications
-
operating temperature: -25°C to +40°C
-
relative humidity: ≤ 85%
-
safe operating pressure: 0.35 – 0.50 MPa
-
minimum required pressure: 0.35 MPa
-
total system weight: 45–80 kg (including accessories and packaging)
-
package dimensions:
-
case 1: 40.5 × 40 × 72.5 cm
-
case 2: 47 × 47 × 33 cm
-
-
compatible with AC mains and portable generator units
Operation Guide
-
startup: power on the device; display shows “HH” while the cooling fan activates
-
set exposure time: turn the dial to adjust to the desired duration
-
warm-up cycle: always perform a warm-up before operation to stabilize the vacuum in the tube
-
adjust kV: choose the correct voltage based on material thickness
-
start exposure: press “HV” to begin exposure; the system will count down automatically
-
post-exposure: once the countdown ends, the unit shuts off the high voltage and begins a cooling cycle
Delay Mode Setup:
-
hold the “HV” key for 3 seconds to enter delay setting
-
select delay time (0.1–5 minutes)
-
release button to save and press again to activate
-
to cancel, either restart the device or press “HV” again to show “00”
Safety Guidelines
-
use 2 mm thick lead shielding or maintain a 20-meter safety radius
-
always ensure the unit is properly grounded
-
do not operate the system if pressure drops below 0.35 MPa
-
never power off the unit during its rest cycle to allow proper cooling
-
voltage fluctuations may trigger automatic protection features, which are part of normal operation
The Mitech XXHA-2505 delivers dependable, high-resolution X-ray inspection capabilities with built-in safety systems and advanced control features, making it a valuable tool for professionals involved in structural analysis, maintenance, and industrial quality assurance.