HYDRANAL™ Titrant 2 34811 Fluka is a methanol-based titrating agent developed for volumetric two-component Karl Fischer titration. This reagent is intended for accurate water content determination in laboratory samples and is specifically formulated to support reliable performance in two-component KF titration procedures.

Product Overview

HYDRANAL™ Titrant 2 is designed for laboratories that require consistent and precise moisture analysis using volumetric two-component Karl Fischer methods. Its methanol-based formulation provides dependable titration behavior and is suitable for routine as well as analytical applications involving water determination in a variety of sample types.

Specifications

This product has passed the suitability test for Karl Fischer titration. It has a water equivalent titer range of 1.96 to 2.06 mg/ml, allowing accurate and controlled moisture determination in two-component volumetric titration systems.

Physical and Chemical Properties

HYDRANAL™ Titrant 2 is supplied as a brown liquid with a density of 0.800 g/cm³ at 20 °C. It has a boiling point of 65 °C at 1.013 hPa and a flash point of 11 °C. The reagent has a melting point of -98 °C, is completely miscible with water, and has a neutral pH value. Its vapor pressure is 128 hPa at 20 °C. The lower explosion limit is 5.5% (V), while the upper explosion limit is 31% (V).

Compatibility and Application

This reagent is intended for volumetric two-component Karl Fischer titration and is suitable for laboratories performing precise moisture determination with methanol-based chemistry. It supports stable titration performance and is compatible with standard Karl Fischer titration equipment used for two-component analysis. The product should be kept away from oxidizing agents.

Safety Information

HYDRANAL™ Titrant 2 is classified under GHS02 (Flammable), GHS06 (Toxic), and GHS08 (Health Hazard). During handling, users should avoid breathing dust, fumes, gas, mist, vapors, or spray. Appropriate protective gloves, protective clothing, eye protection, and face protection should always be used. If ventilation is insufficient, respiratory protection is recommended. The product is listed under Hazard Class 3, Package Group II, with UN ID UN1230.