Swing-out rotor 4-place Cat : 4784-A Hettich
Rp123
The Hettich Swing-out Rotor 4784-A is a high-capacity rotor designed to handle larger sample volumes with precision and safety. With a maximum capacity of 4 × 600 ml, this rotor is particularly suitable for laboratories that require reliable performance in processing medium-to-large sample volumes. Its swing-out configuration keeps tubes in a horizontal orientation during centrifugation, ensuring even sedimentation and optimal clarity of supernatants.
Swing-out Rotor 4-place Cat. 4784-A Hettich
Product Description
The Hettich Swing-out Rotor 4784-A is a high-capacity rotor designed to handle larger sample volumes with precision and safety. With a maximum capacity of 4 × 600 ml, this rotor is particularly suitable for laboratories that require reliable performance in processing medium-to-large sample volumes. Its swing-out configuration keeps tubes in a horizontal orientation during centrifugation, ensuring even sedimentation and optimal clarity of supernatants.
Operating at speeds up to 4,740 rpm and delivering forces of up to 4,800 × g RCF, the 4784-A provides dependable performance for routine and advanced applications. Safety is enhanced with the inclusion of a Bio-Containment lid, protecting both operators and samples from accidental leakage or contamination.
Constructed from high-quality, durable materials, the 4784-A rotor ensures long service life and consistent reliability in demanding laboratory environments.
Key Features
-
Swing-out rotor design for horizontal tube positioning and uniform separation
-
Large volume capacity: accommodates 4 × 600 ml tubes
-
Maximum speed: 4,740 rpm
-
Maximum RCF: 4,800 × g
-
Fixed 90° angle for optimal separation performance
-
Includes Bio-Containment lid as standard for maximum safety
-
Rugged construction for durability and long-term use
-
Seamlessly compatible with Hettich centrifuge systems
Applications
-
Clinical laboratories processing medium-to-large sample volumes
-
Biotechnology and pharmaceutical laboratories handling cell cultures or bulk fluids
-
Environmental and food testing requiring larger sample throughput
-
Research laboratories requiring secure containment and reliable separations
-
Diagnostic labs where contamination prevention is critical
Technical Specifications
-
Maximum RCF: 4,800 × g
-
Maximum RPM: 4,740 min⁻¹
-
Maximum capacity: 4 × 600 ml
-
Angle: 90°
-
Standard equipment: Includes Bio-Containment lid
-
Catalog number: 4784-A
Conclusion
The Hettich Swing-out Rotor 4784-A is an excellent choice for laboratories that need reliable, safe, and efficient centrifugation of larger sample volumes. With its 600 ml per place capacity, dependable RCF performance, and standard Bio-Containment lid, it provides a robust solution for a wide range of laboratory workflows.
Reviews
There are no reviews yet.