Apera Instruments 2301T-F Conductivity/Temp. Electrode

Rp123

Nama Barang : Apera Instruments 2301T-F Conductivity/Temp. Electrode

Model : Instruments 2301T-F Conductivity/Temp. Electrode

Merek : Apera

Apera Instruments 2301T-F Conductivity/Temp. Electrode

Apera Instruments 2301T-F Conductivity/Temp. Electrode (K=1)

SKU: AI1305

Product Description

The Apera Instruments 2301T-F Conductivity/Temp. Electrode is a conductivity electrode with an integrated temperature sensor designed for simultaneous conductivity and temperature measurement. This electrode is suitable for various laboratory, quality control, water analysis, water treatment, environmental testing, and field measurement needs.

Key Features

  • Combined conductivity and temperature electrode

  • Uses proprietary Brush-Resistant Platinum Black sensor

  • Conductivity measuring range of 0.5 μS/cm to 200 mS/cm

  • Provides accurate and consistent measurement across a wide range

  • Helps minimize electrode polarization

  • Platinum black sensor is resistant to routine use and easy to clean

  • Built-in temperature sensor for simultaneous temperature measurement

  • Uses 30KΩ thermistor

  • Supports Automatic Temperature Compensation (ATC) on compatible meters

  • Electrode constant K=1.0 ±0.2 cm⁻¹

  • Uses POM housing

  • Suitable for laboratory use and field testing

  • Equipped with detachable probe storage cap

  • Storage cap helps keep the sensor hydrated when not in use

  • Uses BNC/RCA connection

  • A single electrode can be used for conductivity and temperature measurement

  • Suitable for various water quality and solution testing applications

Specifications

Conductivity 

  • Measurement Range: 0.5 μS/cm to 200 mS/cm

  • Electrode Constant: K=1.0 ±0.2 cm⁻¹

  • Sensor Type: Brush-Resistant Platinum Black

  • Sensor Technology: Proprietary Apera platinum black conductivity sensor

  • Measurement Characteristic: High accuracy and consistency

  • Polarization: Reduced electrode polarization

  • Sensor Maintenance: Easy to clean

Temperature

  • Temperature Sensor: Built-in

  • Sensor Type: 30KΩ Thermistor

  • Temperature Measurement: Simultaneous with conductivity

  • Temperature Compensation: Automatic Temperature Compensation (ATC)

  • ATC Compatibility: Compatible instruments supporting the integrated temperature sensor

Electrode Construction

  • Housing Material: POM

  • Electrode Dimension: Ø12 × 155 mm

  • Electrode Constant: K=1.0 ±0.2 cm⁻¹

  • Conductivity Sensor: Brush-Resistant Platinum Black

  • Temperature Sensor: Integrated 30KΩ thermistor

  • Storage Cap: Detachable

  • Housing Application: Laboratory and field use

Connection

  • Connector: BNC/RCA

  • Conductivity Connection: BNC

  • Temperature Connection: RCA

  • Connection Type: Dual connector for conductivity and temperature

Brush-Resistant Platinum Black Technology

The Apera 2301T-F uses a Brush-Resistant Platinum Black conductivity sensor designed to provide consistent measurement performance across a wide conductivity range.

Platinum black technology helps reduce the effects of electrode polarization that can affect reading stability. The sensor structure is also designed to have good durability for routine use and to simplify the cleaning process after measurement.

With a range of 0.5 μS/cm to 200 mS/cm, the electrode can be used for measuring various types of solutions, both with low and high conductivity.

POM Housing

The 2301T-F uses a POM housing designed to support routine use in both laboratory and field environments. This housing provides a strong electrode construction suitable for various measurement needs.

With dimensions of Ø12 × 155 mm, the electrode design is compact enough to be used in various suitable sample containers.

Detachable Probe Storage Cap

The 2301T-F is equipped with a detachable probe storage cap that helps maintain the sensor’s condition by keeping it hydrated when the electrode is not in use.

Proper storage is important for maintaining the sensor’s condition and helping preserve measurement performance. The storage cap makes the electrode more practical to store after use and before being used again.

Applications

The Apera Instruments 2301T-F Conductivity/Temp. Electrode is suitable for various measurement needs, including:

  • Water analysis

  • Water quality testing

  • Water treatment

  • Environmental testing

  • Laboratory research

  • Quality control

  • Solution testing

  • Water conductivity measurement

  • Sample temperature measurement

  • Field testing

  • Educational laboratories

  • Water quality monitoring

  • Routine testing of various types of solutions

Summary 

The Apera Instruments 2301T-F Conductivity/Temp.  This electrode uses a proprietary Brush-Resistant Platinum Black sensor with a wide measuring range of 0.5 μS/cm to 200 mS/cm.

With an electrode constant of K=1.0 ±0.2 cm⁻¹, platinum black technology helps provide accurate and consistent measurements while reducing the effects of electrode polarization. The sensor is also designed for routine use and is easy to clean.

The integrated 30KΩ thermistor enables simultaneous temperature measurement and supports Automatic Temperature Compensation (ATC) on compatible instruments. Meanwhile, the POM housing provides a construction suitable for both laboratory and field use.

The detachable probe storage cap feature helps keep the sensor hydrated when not in use. The BNC/RCA connection allows the conductivity and temperature sensors to connect to compatible instruments.

With the combination of platinum black sensor, integrated temperature sensor, POM housing, storage cap, and a measuring range of up to 200 mS/cm, the Apera 2301T-F is suitable for various laboratory, water analysis, quality control, water treatment, environmental testing, and field testing applications.

Reviews

There are no reviews yet.

Be the first to review “Apera Instruments 2301T-F Conductivity/Temp. Electrode”

Your email address will not be published. Required fields are marked *

Let's Chat!