
Apera TN500 Portable White Light Turbidity Meter with GLP Data Logger
Rp123
Nama Barang : Apera TN500 Portable White Light Turbidity Meter with GLP Data Logger
Model : TN500 Portable White Light Turbidity Meter with GLP Data Logger
Merek : Apera
Apera TN500 Portable White Light Turbidity Meter with GLP Data Logger
Apera TN500 Portable White Light Turbidity Meter with GLP Data Logger – EPA 180.1 Compliant
SKU: AI483
Product Description
The Apera TN500 Portable White Light Turbidity Meter is a portable water turbidity measuring instrument designed for high-accuracy testing in accordance with the U.S. EPA 180.1 standard. This instrument uses a tungsten filament lamp as its light source and a 90° scattering measurement method, making it highly suitable for water analysis with low turbidity levels as well as general water testing applications.
The TN500 is equipped with TruRead™ Multi-Reading Mode technology, which performs multiple measurements in sequence and calculates the average, minimum, and maximum values. This feature helps produce more representative readings compared to relying on a single measurement result.
To support long-term use, the tungsten lamp can be replaced by the user. The TN500 also uses AMCO Polymer or Formazin calibration standards at 0, 20, 100, 400, and 800 NTU/FNU points. The provided AMCO standards are non-toxic, NIST-traceable, stable, and designed to simplify the calibration process.
The instrument features GLP data management with storage capacity for up to 200 data sets, calibration date and time recording, and USB connection for data transfer to a PC using PC-Link software. With a 3.7V rechargeable lithium battery, the TN500 can be used for approximately 20 hours of testing and can be recharged via USB.
An IP67-protected housing, rugged design, TFT color screen, and multi-language support make the TN500 suitable for both laboratory use and field work.
Key Features
-
EPA 180.1 Compliant with 90° scattering measurement method
-
Uses tungsten filament lamp for high sensitivity in low turbidity measurements
-
Tungsten lamp can be replaced by the user
-
TruRead™ Multi-Reading Mode for repeated measurements and calculation of average, minimum, and maximum values
-
Wide measuring range up to 0–1000 NTU/FNU with automatic range switching
-
Zero-point calibration to help maintain accuracy in low turbidity measurements
-
Equipped with error reminder to help detect calibration errors
-
AMCO Polymer or Formazin calibration standards: 0, 20, 100, 400, and 800 NTU/FNU
-
Data storage for up to 200 groups
-
Calibration date and time recording for GLP requirements
-
USB data output to PC via PC-Link software
-
TFT color screen with on-screen operation guide
-
Supports English, Spanish, and Chinese languages
-
3.7V rechargeable lithium-ion battery with up to approximately 20 hours of use
-
Charging via USB charger or PC
-
Waterproof and dust-proof housing with IP67 rating
-
Suitable for laboratory use and field work
Specifications
Measurement
-
Measurement Method: 90° scattering measurement
-
Compliance: U.S. EPA 180.1
-
Light Source: Tungsten filament lamp
-
Detector: Silicon photovoltaic
-
Measuring Range: 0–1000 NTU/FNU
-
Range 1: 0.01–19.99 NTU/FNU
-
Range 2: 20.0–99.9 NTU/FNU
-
Range 3: 100–1000 NTU/FNU
-
Range Switching: Automatic
-
Accuracy: ≤ ±2% of reading + stray light
-
Repeatability: ≤ ±1% of reading or 0.02 NTU/FNU, whichever is greater
-
Resolution: 0.01 / 0.1 / 1 NTU/FNU
-
Stray Light: ≤0.02 NTU/FNU
Calibration
-
Calibration Standard: AMCO Polymer or Formazin Solution
-
Calibration Points: 0, 20, 100, 400, 800 NTU/FNU
-
Calibration Record: Calibration date and time
-
Zero-point calibration: Yes
-
Error reminder: Yes
Measurement & Data Management
-
Measuring Mode: Normal Measurement and TruRead™ Measurement
-
Data Storage: 200 groups
-
Data Output: USB to PC
-
PC Connectivity: PC-Link software
-
GLP Data Management: Yes
-
Display: TFT color screen
Sample
-
Sample Vial: Ø25 × 60 mm
-
Material: High borosilicate glass with lid
-
Sample Volume: 18 mL
Power
-
Power Supply: 3.7V rechargeable lithium battery
-
Continuous Operating Time: Up to approximately 20 hours
-
Charging: USB charger or PC
Environmental & Physical
-
Working Temperature: 0–50°C (32–122°F)
-
Relative Humidity:
-
0–90% at 30°C
-
0–80% at 40°C
-
0–70% at 50°C
-
-
Condensation: No condensation
-
Instrument Sealing Grade: IP67
-
Meter Dimensions: 90 × 203 × 80 mm
-
Meter Weight: 385 g
-
Test Kit Dimensions: 310 × 295 × 110 mm
-
Test Kit Weight: 1.5 kg
Certification & Warranty
-
Certificates: ISO9001:2015 and CE
-
Limited Warranty: 2 years
Applications
The Apera TN500 can be used for turbidity measurement in various applications, such as:
-
Drinking water testing
-
Tap water
-
Environmental water
-
Wastewater
-
Water treatment
-
Laboratory quality control
-
Field water quality monitoring
-
Testing of samples with low turbidity levels
Summary
The Apera TN500 Portable White Light Turbidity Meter is a portable turbidity meter with EPA 180.1 standard compliance, tungsten filament lamp, TruRead™ Multi-Reading Mode, GLP data storage, USB data output, and IP67 protection. With a measuring range of up to 1000 NTU/FNU and resolution down to 0.01 NTU/FNU, the TN500 is designed for accurate, practical turbidity testing and can be used in both the laboratory and the field.





Reviews
There are no reviews yet.